Quick Start ​

Factory Defaults ​

Wire power, ground, and communication lines according to the model datasheet (verify interface voltage levels). Connect with the factory defaults below (some models ship with different defaults; if parameters were changed, read them back with LOG COMCONFIG / LOG USRCONFIG):

SettingFactory DefaultNotes
Serial port115200 bps, 8N1Same port handles both ASCII commands and binary frames
Serial outputCOM1 outputs HI91 at 100 HzRS-485 models do not stream by default; they respond only to commands and Modbus requests
Mode & axes6-axis (PROFILE=0), Right-Front-Up (COORD 0), standard mounting (URFR 024)No attitude zero offset
Modbus / I2C addressSlave ID 80 (0x50)Shared as the 7-bit I2C address on -I2C models
CANNominal 500 kbit/s, node address 8Broadcasts acc, gyro, roll/pitch, and yaw at 100 Hz (J1939)

Verify Communication ​

View Data in CHCenter ​

  1. Install and open CHCenter from Software & Development.
  2. Select the serial port and baud rate (default 115200), or the CAN channel and bit rate (default 500 kbit/s).
  3. Click Connect and rotate the module; moving plots and 3D attitude confirm a working link.

Verify the Serial Command Channel ​

Open the serial port at 115200 8N1. Commands must be all uppercase and terminated with CR+LF (\r\n). Non-RS-485 models stream binary frames continuously, so pause output with LOG DISABLE before querying the version, then resume with LOG ENABLE (neither command is saved; streaming resumes automatically after reboot):

text
→ LOG DISABLE
← OK
→ LOG VERSION
← PNAME=<model>
← BUILD=<build date>
← UUID=<chip ID>
← SN=<serial number>
← APP_VER=<firmware version integer>
← BL_VER=<bootloader version>
← OK
→ LOG ENABLE
← OK

Receiving OK confirms bidirectional serial communication. Include the complete LOG VERSION output whenever contacting technical support.

Recognize the First HI91 Frame ​

(Skip this step on RS-485 models, which do not stream by default.) After resuming output, switch the serial terminal to hexadecimal (HEX) view. An 82-byte HI91 frame arrives every 10 ms:

text
5A A5 4C 00 .. .. 91 ...

Here 5A A5 is the sync header, 4C 00 is the 76-byte payload length (little-endian), the next 2 bytes are CRC, and 91 is the HI91 tag (83 for HI83). See Serial Binary Protocol for full decoding.

First Check on Other Interfaces ​

InterfaceQuick Check
Modbus RTUConfirm baud rate and slave ID (default 0x50); on non-RS-485 models, send LOG DISABLE to pause output temporarily (use LOG HI91 ONTIME 0 + SAVECONFIG for permanent Modbus operation), then read version registers 0x0070–0x0082
CAN (J1939)Install 120 Ω termination resistors and ensure another node sends ACK; 29-bit extended frames such as 0x0CFF3408 appear on power-up
I2CWrite 10 00 to request the latest HI83 frame and read back the 6-byte header, checking for 5A A5

Power-Up Stillness ​

Keep the module stationary for at least 3 s after power-up to finish initialization and attitude convergence:

  • Discard any all-zero frames emitted right after power-up.
  • After 3 s of stillness, check MAIN_STATUS.ATT_CONV: 0 means roll and pitch have converged; 1 means not yet converged.
  • In 9-axis mode, also wait until MAG_DIST clears to 0 before trusting magnetic heading.

If communication fails or the link is lost, see Troubleshooting & Firmware Upgrade.