Quick Start
Factory Defaults
Wire power, ground, and communication lines according to the model datasheet (verify interface voltage levels). Connect with the factory defaults below (some models ship with different defaults; if parameters were changed, read them back with LOG COMCONFIG / LOG USRCONFIG):
| Setting | Factory Default | Notes |
|---|---|---|
| Serial port | 115200 bps, 8N1 | Same port handles both ASCII commands and binary frames |
| Serial output | COM1 outputs HI91 at 100 Hz | RS-485 models do not stream by default; they respond only to commands and Modbus requests |
| Mode & axes | 6-axis (PROFILE=0), Right-Front-Up (COORD 0), standard mounting (URFR 024) | No attitude zero offset |
| Modbus / I2C address | Slave ID 80 (0x50) | Shared as the 7-bit I2C address on -I2C models |
| CAN | Nominal 500 kbit/s, node address 8 | Broadcasts acc, gyro, roll/pitch, and yaw at 100 Hz (J1939) |
Verify Communication
View Data in CHCenter
- Install and open CHCenter from Software & Development.
- Select the serial port and baud rate (default
115200), or the CAN channel and bit rate (default500 kbit/s). - Click Connect and rotate the module; moving plots and 3D attitude confirm a working link.
Verify the Serial Command Channel
Open the serial port at 115200 8N1. Commands must be all uppercase and terminated with CR+LF (\r\n). Non-RS-485 models stream binary frames continuously, so pause output with LOG DISABLE before querying the version, then resume with LOG ENABLE (neither command is saved; streaming resumes automatically after reboot):
→ LOG DISABLE
← OK
→ LOG VERSION
← PNAME=<model>
← BUILD=<build date>
← UUID=<chip ID>
← SN=<serial number>
← APP_VER=<firmware version integer>
← BL_VER=<bootloader version>
← OK
→ LOG ENABLE
← OKReceiving OK confirms bidirectional serial communication. Include the complete LOG VERSION output whenever contacting technical support.
Recognize the First HI91 Frame
(Skip this step on RS-485 models, which do not stream by default.) After resuming output, switch the serial terminal to hexadecimal (HEX) view. An 82-byte HI91 frame arrives every 10 ms:
5A A5 4C 00 .. .. 91 ...Here 5A A5 is the sync header, 4C 00 is the 76-byte payload length (little-endian), the next 2 bytes are CRC, and 91 is the HI91 tag (83 for HI83). See Serial Binary Protocol for full decoding.
First Check on Other Interfaces
| Interface | Quick Check |
|---|---|
| Modbus RTU | Confirm baud rate and slave ID (default 0x50); on non-RS-485 models, send LOG DISABLE to pause output temporarily (use LOG HI91 ONTIME 0 + SAVECONFIG for permanent Modbus operation), then read version registers 0x0070–0x0082 |
| CAN (J1939) | Install 120 Ω termination resistors and ensure another node sends ACK; 29-bit extended frames such as 0x0CFF3408 appear on power-up |
| I2C | Write 10 00 to request the latest HI83 frame and read back the 6-byte header, checking for 5A A5 |
Power-Up Stillness
Keep the module stationary for at least 3 s after power-up to finish initialization and attitude convergence:
- Discard any all-zero frames emitted right after power-up.
- After 3 s of stillness, check
MAIN_STATUS.ATT_CONV:0means roll and pitch have converged;1means not yet converged. - In 9-axis mode, also wait until
MAG_DISTclears to0before trusting magnetic heading.
If communication fails or the link is lost, see Troubleshooting & Firmware Upgrade.